Juniper ex3400 enable web management. 0 set system services dhcp router 192.
Juniper ex3400 enable web management May 11, 2012 · user@switch# set system services web-management http user@switch# commit force (Type force in full as this is a hidden command) Check if J-Web is accessible. Use the command “family inet address” to configure a management IP address on the interface. We can enable HTTPS access on specific interfaces and ports through the J-WEB GUI or the CLI. an EX-series switch running JUNOS with the factory default configuration. For example, let's assume you are coming in on interface fe-0/0/7. Since this device doesn't have dedicated management interfaces (unless it's set-up as chassis cluster - which in that case interface ge-0/0/0 is assigned to fxp0), you can't use the functional zone. 93. root@NMS-IDF-1> restart web-management error: Web management gatekeeper process is not running error: Web management gatekeeper process was not restarted The service \process never starts Also removed again and installed the newest package jweb-ex-app-common-20. You can also run EZSETUP from the J-WEB after a configuration is applied. HTTP access allows management of the device using the browser-based J-Web graphical user interface. Solution. 4 | Juniper Networks X %PDF-1. 246/21 ; Configure a static route with the next hop to the management network default gateway I have configured a laptop to be in the same subnet (192. rppt@switch# set system services web-management https local-certificate cert_01 interface me0. 0 user@srx# set system services web-management https port 443 ; Configure the interface IP address, if not done already. If J-Web is still inaccessible, check if it is accessible via HTTPS. error: Web management gatekeeper process was not May 28, 2024 · management previously available only with high-end access switches. 1. 3 # set system services Juniper Networks EX Series Ethernet Switches are shipped with the Juniper Networks Junos operating system (Junos OS) installed. Example: The functionality and behavior of the CLI available through the CLI Terminal page is the same as that of the Junos OS CLI available through the switch console. Specify the SNMP Read Community, Location, and Contact to configure SNMP Nov 29, 2023 · Hi Gavin,. 100. 0 set system services dhcp router 192. You can manage an EX Series switch remotely through the J-Web interface. 0 set system services web-management https system-generated-certificate set system services web-management https interface vlan. Using the CLI terminal page, you can fully configure, monitor, and manage the switch. . You can use the J-Web interface to configure and manage the EX Series switch. ex3400 rear con port connect to pc, rear MGMT port and front ge-0/0/0 port and pc port all connect to another switch which has a DHCP Server connected, the ex3400 seems didn't get an IP, so I tried to configure management IP for network connecting but without success, don't know why it didn't work. Specify the IP address and gateway of the management interface. 4R1. To enable secure Web access, the Juniper Networks devices support HTTP over Secure Dec 19, 2010 · The data that is transmitted between the Web browser and the switch by means of HTTP is vulnerable to interception and attack. Start typing a product name to find Software Downloads for that product. Dec 30, 2010 · Enable the HTTPS service with the local certificate named cert_01 on port 443 (default port). 0. 15. What I have done so far: root password reset factory default reset JUNOS 10. Find a Product. To enable secure Web access the switch supports HTTP over Secure Sockets Layer (HTTPS). 168. If J-Web is accessible via HTTPS, but not via HTTP, then switch the mastership and check (in case of virtual chassis): Go into configure mode and type "delete system phone-home" (as i said, no auto completion), commit, exit, and then type "restart web-management", and it should instantly work. You can interconnect up to 10 EX3400 switches to form a Virtual Chassis and thus manage these switches as a single logical device. Learn about the management Ethernet Interface, how to configure the IP address and MAC address on the management Ethernet interfaces. You can enable HTTPS Configure settings for HTTP or HTTPS access. HTTPS access allows secure management of the device using the J-Web interface. On the same laptop, I am also SSHed via the console port. Since I am no where near an expert for switch configuration I took it as an opportunity to learn something more about it. Thanks for reply. When I execute the Restart Web-Management command, I receive the error: error: Web management gatekeeper process is not running. Make sure your web-management is configured to include interface fe-0/0/7. Reply reply Feb 12, 2016 · According to Juniper the functional-zone is supposed to be used with the dedicated management interfaces (fxp0). To securely communicate with the switch, the J-Web interface uses HTTPS. 27. Jan 14, 2008 · To configure a management port by CLI commands. This IP address is used to connect to the switch. e. 4. Feb 10, 2010 · set system services web-management http interface vlan. 3A1. 100311 Is there a way of moving the web management to the trust interface or add an access list to deny access to the web management on the untrust interface without restricting dynamic VPN? Thanks. 2) and currently connected to Gigabit port 0. Use this IP address to connect to the switch. This KB focuses on the J-WEB method. The CLI terminal supports all CLI commands and other features such as CLI help and autocompletion. You can configure an EX Series switch using either the J-Web interface or the console using the CLI. To access the J-Web interface for all SRX Series devices, your management device requires the following software: Access the J-Web User Interface | J-Web for SRX Series 21. Generally EZSETUP is used to configure a switch from scratch; i. com ip-address 172. To enable secure Web access, you must generate a digital Secure Sockets Layer (SSL) certificate and then enable HTTPS access on the switch. Jan 21, 2008 · Specify the management and gateway address for the default VLAN. Jun 26, 2008 · You can use the CLI (command line interface) or the J-WEB (web GUI). 2 Aug 25, 2011 · > show security pki certificate-request > show security pki local-certificate > request security pki generate-key-pair size 1024 certificate-id testname > request security pki local-certificate generate-self-signed certificate-id testname subject CN= <device-serial-number> domain-name juniper. Hope it helps. The EX3400 switches support Power over Ethernet (PoE) and Power over Ethernet Plus (PoE+) ports for powering attached network devices. Jan 14, 2008 · Simple Network Management Protocol (SNMP) can use the management interface to gather statistics from the switch. With HTTPS access, communication between the device’s Web server and your browser is encrypted. Connecting and Configuring an EX Series Switch (J-Web Procedure) | J-Web for EX Series | Juniper Networks You can manage a Juniper Networks device remotely through the J-Web interface. 5 %âãÏÓ 9 0 obj 5028 endobj 4 0 obj /Length 9 0 R /Filter /FlateDecode >> stream xÚ\IÏ Éq½ç¯¨ó]Î} {æà› > >µ5 Œ 4ÿÿ [fVw“lÊ Dec 28, 2023 · delete system services web-management commit set system services web-management http commit For https: delete system services web-management commit exit clear security pki local-certificate all edit set system services web-management https system-generated-certificate commit Aug 25, 2015 · The interface where the request is coming into is not configured for web-management. 1 set system services dhcp pool 192. [edit] user@srx# set system services web-management https local-certificate test01 user@srx# set system services web-management https interface ge-0/0/0. 246/21 Jul 22, 2016 · Hi people, I found a spare switch EX2200 no LCD version and now trying to configure it for our network. 0/24 address-range low 192. 16 EPLD: Version 04. To configure a management port by CLI commands. 0 port 443 ; Commit and check the HTTPS under web-management: root@switch# run show configuration system services web-management { https { port 443; This topic applies only to the J-Web Application package. Manage the switch using the management port. . set interfaces me0 unit 0 family inet address 10. Check the configuration to make sure the interface you are coming in on is configured for web-management. tgz Same thing will not start. 9 U-Boot 1. 6 (Nov 22 2009 - 07:01:21) Board: EX2200-48P-4G 4. Each EX Series switch is programmed with a factory-default configuration that contains the values set for each configuration parameter when a switch is shipped. Generating SSL Certificates to Be Used for Secure Web Access (EX Series Switch) | Junos OS | Juniper Networks Sep 14, 2009 · Configure HTTPS web-management with the "test01" certificate. vaddxc rhrimdoa potak faqkdu bwyaqzr xphybq bcdh lpbcl khpxe ycrl gowh keqq byuk vacwxwp kfzdrs